HomeProductsHydraulic Pressure Control ValveIndustrial Hydraulic Pressure Control Valve Low Noise Pilot Operated Safety Relief Valve



Industrial Hydraulic Pressure Control Valve Low Noise Pilot Operated Safety Relief Valve
Negotiable
Product Description
Pressure Low Noise Type S-BG Pilot Operated Relief Valve
Features
Pilot operated relief valves here have been particularly developed as low-noise types. Able to protect pumps and control valves against excessive pressures, they are used to control the pressure in the hydraulic system to a constant level. Remote control and unloading are permitted by using vent circuits
Specifications
|
Model Numbers
|
Max. Operating Pressure (Mpa) |
Pres. Adj. Range (Mpa) |
Max. Flow (L/min) |
Approx. Mass kg (lbs.) |
| S-BG-03-*-*-40 | 25 | Note) -25 | 100 | 4.1 (9.0) |
| S-BG-06-*-*-40 | 200 | 5.0 (11.0) | ||
| S-BG-10-*-*-40 | 400 | 10.5 (23.2) |
Model Number Designation
| F- | S- | B | G | -3 | -V | -L | -40 | * |
| Special Seals | Low Noise Type | Series Number | Type of Mounting | Valve Size | High Venting Pres. Feature | Direction of Handle | Design Number | Design Std. |
| F: Special Seals for Phosphate Ester Type Fluids(Omit if not required) | S: Low Noise Type |
B: Pilot Operated Relief Valves |
G: Sub - plate Mounting |
03 | V: For High Venting Pressure Feature(Omit if not required) | (Viewed from pressure gauge connection) L: Left (Normal) R: Right |
40 | Refer to ★2 |
| 06 | 40 | |||||||
| 10 | —————— | 40 |
★1. Use the high venting pressure type where it is necessary to reduce the response time from unloading to onloading.
★2. Design Standards: None ........ Japanese Standard "JIS" and European Design Standard