DSG-01 Solenoid Operated Directional Valve for Industrial Machinery High Performance
Our next-generation Solenoid Operated Directional Valves deliver exceptional performance in high-pressure, high-flow applications while maintaining an ultra-low pressure drop. This leap in performance is made possible by a high-powered wet-type solenoid and an optimized 5-chamber flow path design.
Superior Pressure & Flow Handling
Significantly outperforms previous generations, offering both higher operating pressure and greater flow capacity.
Minimized Pressure Drop
Engineered for less pressure loss, directly contributing to lower energy consumption for your entire system.
Compact & Lightweight
Despite its high performance, the valve body remains compact and lightweight, especially in the DC double solenoid configuration.
Shockless Operation Option
In addition to the standard high-performance valves, a shockless variant is available to greatly reduce noise and vibration during spool shifts.
Exceptional Operational Stability
The robust magnetic force and strong spring ensure reliable and stable operation, even in the presence of minor contaminants.
Valve Type
|
Model Numbers | Max. Flow L /min (U.S.GPM) |
Max. Operating Pressure MPa (PSI) | Max. T-Line Back Pres. MPa (PSI) | Max. Change over Frequency min-1 (Cycles/Min) |
Approx. Mass (kg) |
Standard Type | DSG-01-3C∗-∗-50 | 63 (16.6) | 31.5 (4570) {Spool Type 60 Only 25(3630)} |
16 (2320) | 300 {R Type Sol. Only 120} |
2.2 |
DSG-01-2D2-∗-50 | 2.2 | |||||
DSG-01-2B∗-∗-50 | 1.6 | |||||
Shock-less Type |
S-DSG-01-3C∗-∗-50 | 40 (10.6) | 16 (2320) | 16 (2320) | 120 | 2.2 |
S-DSG-01-2B2-∗-50 | 1.6 |
Valve Type
|
Electric Source | Coil Type | Frequency (Hz) |
Voltage (V) | Current & Power at Rated Voltage | |||
Source Rating | Serviceable Range | Inrush (A) | Holding (A) | Power (W) | ||||
Standard Type Shock-less Type |
AC | A100 | 50 | 100 | 80 - 110 | 2.42 | 0.51 | ― |
60 | 100 | 90 - 120 | 2.14 | 0.37 | ||||
110 | 2.35 | 0.44 | ||||||
A120 | 50 | 120 | 96 - 132 | 2.02 | 0.42 | |||
60 | 108 - 144 | 1.78 | 0.31 | |||||
A200 | 50 | 200 | 160 - 220 | 1.21 | 0.25 | |||
60 | 200 | 180 - 240 | 1.07 | 0.19 | ||||
220 | 1.18 | 0.22 | ||||||
A240 | 50 | 240 | 192 - 264 | 1.01 | 0.21 | |||
60 | 216 - 288 | 0.89 | 0.15 | |||||
DC (K Series) |
D12 | ― | 12 | 10.8 - 13.2 | ― | 2.45 | 29 | |
D24 | 24 | 21.6 - 26.4 | 1.23 | |||||
D48 | 48 | 43.2 - 52.8 | 0.61 | |||||
AC→DC Rectified (R) | R100 | 50/60 | 100 | 90 - 110 | ― | 0.33 | 29 | |
R200 | 200 | 180 - 220 | 0.16 |
F-
|
S- | DSG | -1 | -2 | B | 2 |
Special Seals | Shock less Type | Series Number | Valve Size | Number of Valve Positions | Spool-Spring Arrangement | Spool Type |
F: For Phosphate Ester Type Fluids (Omit if not Required) |
None: Standard Type |
DSG: Solenoid Operated Directional Valve |
1 | 3 | C: Spring Centered |
2, 3, 4, 40, 60, 9, 10, 12 |
2 | D: No-Spring Detened |
2 | ||||
B: Spring Offset |
2, 3, 8 | |||||
S: Shock-less Type |
3 | C: Spring Centered |
2, 4 | |||
2 | B: Spring Offset |
2 |
A
|
0 | -C | -N | -50 | -L |
Special Two Position Valve (Omit if not Required) |
Coil Type | Manual Override | Electrical Conduit Connection | Design Number | Models with Reverse Mtg. of Solenoid (Omit if not required) |
― | AC: A100 A120 A200 A240 DC: D12 D24 D48 R: (AC→DC) R100 R200 |
None:
|
None:
|
50 | ― |
― | ― | ||||
A B |
L | ||||
― | DC: D12 D24 D48 R: (AC→DC) R100 R200 |
― | |||
― | L |