BM2 series cycloid hydraulic motor (can interchange with OMR series)
1. It adapts the gerolor design, which has a higher distribution accuracy.
2. Shaft seal is adapted, which can bear higher back pressure.
3. A variety of connection types of flange, output shaft and oil port.
4. Direction of shaft rotation and speed can be controlled easily and smoothly.
5. Small volume; compact structure.
Displacement (ml/r)
|
50 | 63 | 80 | 100 | 125 | 160 | 200 | 250 | 315 | 400 | 500 | |
Flow (LPM) |
Continuous | 40 | 53 | 58 | 58 | 58 | 58 | 58 | 58 | 58 | 58 | 58 |
Intermittent | 46 | 58 | 68 | 68 | 68 | 68 | 68 | 68 | 68 | 68 | 68 | |
Speed (RPM) |
Continuous | 750 | 760 | 653 | 551 | 440 | 344 | 276 | 220 | 175 | 140 | 110 |
Intermittent | 863 | 832 | 766 | 646 | 516 | 404 | 323 | 258 | 205 | 162 | 128 | |
Pressure (Mpa) |
Continuous | 14 | 14 | 14 | 14 | 14 | 14 | 12.5 | 11 | 9 | 9 | 8 |
Intermittent | 17 | 17 | 17 | 17 | 17 | 17 | 15 | 13 | 11 | 10 | 9 | |
Torque (N·m) |
Continuous | 89 | 112 | 142 | 178 | 223 | 286 | 318 | 350 | 360 | 418 | 464 |
Intermittent | 108 | 136 | 172 | 216 | 270 | 346 | 382 | 413 | 400 | 464 | 500 |
1. Intermittent means the entrance of the maximum pressure; continuous working pressure means the differential pressure.
2. Motor should not work under the highest pressure and the maximum speed.
3. The running time should not exceed 10% under intermittent working conditions.
4. The maximum working temperature is 80°.
5. The maximum allowable back pressure is 10MPa, but the recommended back pressure should not exceed 5MPa. A leaking pipe is needed when exceeding.
6. One hour running time under 40% of maximum working pressure is recommended before full capacity working.
7. Recommending N68anti-wear hydraulic oil, viscosity 37-73cSt, cleanliness ISO18/13.